D04 — The Wire: RDMA, NVLink, xGMI & InfiniBand

Track D · Module 04 · Status: DONE · Est. 6 hours · Depth 3/5

Prerequisites: D03 for what a collective needs from the fabric, and B01 whose section 3.5 measures the intra-node links this module extends across the network.

Backends: topology introspection labs run on any multi-GPU node. Fabric figures are public vendor specifications with retrieval dates, or clearly-labelled illustrative orders of magnitude. The RDMA labs need an RDMA-capable fabric and will say so rather than pretend; where you do not have one, the analytic tools in tools/ stand in and label their output as a model. Setup: SETUP.md · Terms: GLOSSARY.md · Sources: REFERENCES.md.


1. TL;DR + Layman analogy

TL;DR. Every byte your distributed job moves travels in one of a handful of tiers, and the tiers are separated by roughly an order of magnitude each: on-package memory, then the scale-up links that join GPUs inside a node, then PCIe, then the scale-out network between nodes, then storage. That ladder is the whole subject. It explains why tensor parallelism is confined to one node, why a gradient all-reduce is a network problem and an activation all-reduce is not, and why the single most valuable optimization in distributed computing is not making a tier faster but keeping traffic in the fastest tier that can hold it.

Layered on top of the ladder is one mechanism that decides how much of a tier's advertised bandwidth you actually get: RDMA. RDMA lets a network adapter read and write a remote machine's memory directly, with the remote CPU uninvolved and no intermediate copies. Extended to GPU memory — GPUDirect RDMA on NVIDIA, and the equivalent peer-to-peer DMA path on ROCm — it means a gradient can leave one GPU's HBM and arrive in another's without ever being staged in host RAM. The staged alternative is not slightly worse; it crosses PCIe twice per side, burns host memory bandwidth and a CPU core doing work with no semantic content, and adds two store-and-forward hops of latency in each direction.

Layman analogy — the office building and the courier.

Think of a large firm spread across several buildings.

  • Same desk cluster. Two people at adjacent desks hand documents to each other directly. No packaging, no addressing, no waiting. This is a thread reading its own registers or the shared memory in its own compute unit, and it is so fast it barely registers as movement at all.
  • Same floor. You walk a folder ten metres to a colleague. Still trivial. This is HBM: your own GPU's memory, on the same package.
  • Another floor, same building. There is a pneumatic tube between floors. It is fast and purpose-built, and you can send a lot through it, but you have to load a canister, and the tube is shared with everyone else on your floor. This is the scale-up link — NVLink or xGMI — between GPUs in one node.
  • Another building. Now you need a courier. There is a loading dock, a van, traffic, another loading dock. It works, it is reliable, and it is one to two orders of magnitude slower per document than the tube. This is the scale-out network.
  • The off-site records warehouse. Slower again, and you plan around it rather than reacting to it. This is storage.

Two predictions follow, and both are load-bearing for the rest of the module.

The cliff is multiplicative, not additive. Each step down is not "a bit slower"; it is a factor. So a design decision that moves a hot data flow from the tube to the courier does not cost you 20%, it costs you most of your machine. This is why "which tier does this traffic live in" is a more consequential question than any amount of kernel tuning, and why the answer is usually decided by where you placed the work, not by how you wrote it.

Staging through an intermediary costs more than it looks like it should. Suppose the courier is not allowed into your building. Instead you hand every document to a receptionist in the lobby, who photocopies it into a standard envelope, files a record, and hands it to the courier; and on the far side another receptionist opens the envelope, re-files the contents into the recipient's cabinet, and only then tells them it arrived. Notice what that costs. The document crosses the lobby twice on each side rather than once. Both receptionists are fully occupied doing clerical work that adds nothing to the document. And the recipient learns about it later than they had to. Now let the courier walk straight to the recipient's filing cabinet, with a key that was cut in advance, and put the pages directly into the correct drawer without waking anybody. That is RDMA, and "zero-copy" means precisely this: no intermediate buffer, no receptionist, no photocopy. The wire time did not change at all — what disappeared is everything that was not wire time.

Where the analogy breaks, in four places that all matter later:

  1. The tiers differ in kind, not only in speed. A peer GPU's memory in the scale-up domain is addressable: a kernel can issue an ordinary load or store against it, the same instruction it would use for its own HBM. Nothing across the network is addressable in that sense. Crossing it always means posting a descriptor to a queue and waiting for a completion — an I/O operation, not an instruction. There is no analogy for that in a building; it is closer to the difference between reaching for a folder and filing a request.
  2. The courier cannot go anywhere they like. RDMA into a remote process's memory only works on regions that were registered in advance, pinned so the operating system cannot move them, and whose keys were exchanged. The key is cut per drawer, and cutting keys is expensive — which is why real systems cache registrations aggressively and reuse buffers rather than allocating fresh ones.
  3. There is a limit on how fast you can hand things to the courier, independent of how fast the van drives. A node's network adapters set an injection rate. Eight GPUs sharing one adapter share one loading dock, and a wider motorway does not help. This is LogP's gap parameter from D01 §3.2, and section 3.6 makes it quantitative.
  4. The roads are shared and they push back. One congested intersection in a lossless network can propagate backwards and stall traffic that was never going anywhere near it. That failure mode — congestion spreading — has no counterpart in a courier network and is the single hardest thing about running RDMA over Ethernet. Section 3.3 explains the mechanism.

By the end of this module you can read a topology matrix on either vendor and say, for any pair of GPUs, whether they have a direct link or a host hop; explain what a copy actually costs when it stages through host memory and what GPUDirect removes; describe the RDMA data path in terms of queue pairs, registrations and completions; name the specific mistake that makes lossless Ethernet worse than lossy Ethernet; and compute the injection ceiling of a node before you buy it.


2. First Principles

2.1 The bandwidth tier ladder

The bandwidth cliff from HBM to the network

Every performance argument in distributed GPU computing is a statement about this ladder. The figures below are illustrative orders of magnitude, not a datasheet quote for any specific part. They are deliberately imprecise, because the point is the ratio between rows — which is stable across generations — and not any row's value, which is not. They extend D01 §3.1's table downward into memory and upward into storage. Verified per-part numbers for the two middle rows, with sources and retrieval dates, are in B01 §3.5; this module does not reprint them.

Tier Where it physically is Bandwidth, order of Latency, order of How software reaches it
Register file, shared memory / LDS inside the compute unit 10s of TB/s ~ns an instruction
Last-level or Infinity Cache on package ~TB/s 10s of ns implicit, on a miss
HBM on package ~TB/s 100s of ns load and store
Scale-up GPU-GPU link inside one node 100s of GB/s ~1-2 us for a small transfer load and store, or a DMA copy
PCIe, GPU to host or to NIC inside one node 10s of GB/s ~1-2 us DMA
Scale-out RDMA fabric, per adapter between nodes 10s of GB/s ~2-5 us DMA, posted through verbs
Datacenter Ethernet over TCP between nodes ~GB/s 10s-100s of us kernel sockets
Networked or parallel storage, per client rack and beyond 100s of MB/s to GB/s 100s of us to ms filesystem calls

Read the table as a staircase with roughly a decade per step, and note two structural facts that the bandwidth column alone hides.

The latency column falls apart faster than the bandwidth column. From HBM to the network, bandwidth drops by about two orders of magnitude but latency rises by about four. That asymmetry is why small messages are so much worse across the network than a bandwidth ratio suggests, and it is the mechanical reason D01's crossover point m* moves the way it does.

Addressability stops partway down. Everything at or above the scale-up row can be reached with a load or a store. Everything below it requires an explicit transfer, posted somewhere, completed later. That boundary — not a bandwidth number — is the real reason tensor parallelism and data parallelism have such different fabric requirements, and section 3.1 makes it the organizing distinction of the module.

2.2 The one organizing rule

If a tier moves B bytes per second and your working traffic is m bytes, that traffic costs m/B seconds in whichever tier it lands. Nothing about that is subtle. What makes it the central rule of distributed computing is that B varies by four orders of magnitude across the ladder while m is usually fixed by the algorithm:

cost of a data flow = m / B(tier it was placed in)

So the tier assignment dominates every other decision about that flow. Moving a flow one step down the ladder costs you roughly a factor of ten; no amount of kernel optimization recovers a factor of ten. Hence the rule, which is worth stating in the imperative because every later section is an application of it:

[!IMPORTANT] Keep each flow in the fastest tier that can hold it, and make the flows that must cross a tier boundary as few and as large as possible.

This one sentence generates: keep tensor parallelism inside the scale-up domain; bucket gradients before crossing the network; shard so that what must be all-reduced is small; put the KV cache in HBM and not across PCIe; and overlap what you cannot avoid. Every one of those is the same rule applied to a different flow.

The corollary is the diagnostic habit. When something is slower than expected, the first question is never "how do I make this faster" — it is "which tier is this actually running in, and did I think it was running in a faster one?" Most large distributed-performance surprises are a flow that quietly fell one tier down the ladder: peer access not enabled, GPUDirect not on the fast path, a NIC on the wrong PCIe root, a rank placed on the wrong GPU.

2.3 What a copy costs when it is staged through the host

Now derive the concrete case. A rank on node A wants m bytes of GPU memory to arrive in a GPU on node B. Compare two paths segment by segment.

Staged through host memory — the path you get if nothing has been arranged:

Step What moves Resource consumed
1 GPU HBM to host buffer PCIe (GPU to host), host memory write bandwidth
2 host buffer to a pinned, registered buffer, if step 1 did not land in one host memory read plus write, and a CPU core
3 pinned buffer to the network adapter PCIe again (host to NIC), host memory read bandwidth
4 the wire the fabric
5 adapter to a pinned host buffer on node B PCIe, host memory write
6 pinned buffer to GPU HBM PCIe again, host memory read

Direct, with GPUDirect RDMA or the equivalent peer-to-peer DMA path:

Step What moves Resource consumed
1 the adapter reads GPU HBM directly, through the GPU's PCIe BAR PCIe (GPU to NIC), once
2 the wire the fabric
3 the remote adapter writes the destination GPU's HBM directly PCIe, once

Count the differences rather than guessing at a speedup:

  • PCIe traversals: four versus two. The staged path crosses the local PCIe complex twice on each side. Whether that costs you wall time depends on whether PCIe is comfortably wider than the wire. When it is, the penalty is modest. When it is not — a narrow slot, a link trained down, or several GPUs sharing one switch uplink — the staged path is directly half throughput, because you doubled demand on the narrowest link in the path. Section 3.7 is about how often this is the case.
  • Host memory traffic: roughly 4m versus zero. The staged path pushes four times the message size through the host memory system, and that bandwidth is not free — it is shared with your data loader, your tokenizer, and every other rank on the node.
  • Latency: two extra store-and-forward hops per side. Each staging step must complete before the next begins for a given chunk. Pipelining into chunks hides most of this for large messages and almost none of it for small ones, which is why the staged path degrades hardest exactly where the latency term already dominates.
  • A CPU core, and synchronization. Someone has to issue the copies and know when they finished. That is host work interleaved with the compute stream, and it is the mechanism behind the "GPU utilization drops during communication" symptom.

Round invented numbers, purely to see the shape and not a measurement of anything: take a PCIe path that sustains 20 GB/s and a network path that sustains 10 GB/s, with m = 1 GB. Serially, the staged path is 0.05 + 0.05 + 0.10 + 0.05 + 0.05 = 0.30 s and the direct path is 0.05 + 0.10 + 0.05 = 0.20 s. Perfectly pipelined, both are bounded by their busiest resource and the gap narrows sharply. The honest conclusion is therefore not "staging is always 1.5x slower" — it is:

Staging costs bandwidth only when PCIe is the narrow link, but it always costs latency, host memory bandwidth, and CPU time. Which of those hurts depends on your message size distribution, and that is a thing you can measure.

That nuance matters, because the confident claim "GPUDirect gives you 2x" is usually wrong, while the claim "GPUDirect removes a class of interference and a chunk of fixed latency, and protects you when PCIe is tight" is defensible. Section 4's lab measures your own case; the tool in tools/staging_cost.py prints both the serial and the pipelined bound and labels itself a model.


3. Deep Dive

3.1 Scale-up and scale-out: the distinction everything hangs on

The single most useful way to organize interconnect knowledge is not by vendor and not by generation. It is by which of two jobs the link is doing.

%%{init: {'theme': 'base', 'themeVariables': {'primaryColor': '#F8FAFC', 'primaryBorderColor': '#DB2777', 'lineColor': '#64748B', 'fontFamily': 'Inter, sans-serif'}}}%%
flowchart TB
  subgraph NODEA["Node A - one scale-up domain"]
    direction TB
    GA0["GPU0 + HBM"]
    GA1["GPU1 + HBM"]
    GA0 <-->|"scale-up link: NVLink or xGMI<br/>addressable, 100s of GB/s"| GA1
    PSWA["PCIe switch / root complex"]
    GA0 ---|"PCIe"| PSWA
    GA1 ---|"PCIe"| PSWA
    NICA["Network adapter (HCA or NIC)"]
    PSWA ---|"PCIe"| NICA
    CPUA["Host CPU + system memory"]
    PSWA --- CPUA
  end

  subgraph NODEB["Node B - a different scale-up domain"]
    direction TB
    NICB["Network adapter"]
    PSWB["PCIe switch / root complex"]
    GB0["GPU0 + HBM"]
    NICB ---|"PCIe"| PSWB
    PSWB ---|"PCIe"| GB0
  end

  NICA <-->|"scale-out fabric: leaf and spine switches<br/>not addressable, 10s of GB/s per adapter"| NICB

  classDef trackD fill:#DB2777,stroke:#0F172A,color:#fff
  classDef neutral fill:#F8FAFC,stroke:#DB2777,color:#0F172A
  class GA0,GA1,GB0 trackD
  class PSWA,PSWB,NICA,NICB,CPUA neutral

The two GPUs in node A can reach each other's memory with a load or a store. Reaching GPU0 of node B requires leaving the addressable world: a descriptor posted to the adapter, a DMA, a wire, another DMA, a completion. That change of kind, not the change in bandwidth, is why the two halves of this diagram need entirely different software.

Scale-up Scale-out
Joins GPUs within a node or a tightly-coupled group nodes to each other
Examples NVIDIA NVLink and NVSwitch; AMD xGMI, part of the Infinity Fabric family InfiniBand, RoCEv2, AWS EFA, HPE Slingshot
Access model peer memory is addressable; load, store, or DMA DMA only, posted through a queue
Coherence coherent or near-coherent within the domain none
Bandwidth per GPU 100s of GB/s (order of) 10s of GB/s per adapter (order of)
Latency for a small transfer ~1-2 us (order of) ~2-5 us (order of)
Scales to a node, or a small number of tightly-coupled nodes thousands of nodes
What must stay inside tensor parallelism; any collective on the token critical path nothing has to; everything can

The terms are in the glossary as NVLink, xGMI and Infinity Fabric and InfiniBand, RoCE and Slingshot. Keeping them straight is worth the effort, because almost every confused fabric conversation is two people talking about different halves of that table.

3.2 The scale-up domain, and why tensor parallelism lives in it

B01 §3.5 covers the scale-up tier in measured detail — per-link rates, links per GPU, aggregate peer-to-peer bandwidth, and the structural difference between AMD's direct full mesh and NVIDIA's switched NVSwitch fabric, each with a source and a retrieval date. Read it rather than a summary; this module does not restate those numbers and deliberately does not paraphrase them, because a paraphrased specification is how folklore starts.

What this module adds is the consequence for the network, which is threefold.

The scale-up domain is a boundary, and boundaries are where designs are decided. Inside it, an all-reduce runs at hundreds of GB/s over addressable links. One step outside, the same all-reduce runs at tens of GB/s per adapter over a fabric that is not addressable. The ratio is roughly an order of magnitude, and it lands entirely on whichever parallelism axis you chose to place across the boundary. Since tensor parallelism issues a collective twice per transformer layer with a small payload, and during autoregressive decode those collectives are on the critical path of every token, tensor parallelism is the axis that cannot cross. Data parallelism, whose collective is large and once per step and overlappable with the backward pass, is the axis that can. B07 owns the sharding decision; this section supplies the physical reason it comes out the way it does.

Coherence is a spectrum, and it matters for programming model rather than for bandwidth. Some members of these link families extend hardware cache coherence across the link, up to full CPU-GPU coherence in an APU package — B01 §3.6 covers the MI300A case, where host and device share one address space. The practical consequence is that in a coherent scale-up domain, "communication" can be a load; across scale-out it is always an operation. Never assume a specific coherence guarantee from a marketing name; check the architecture document for the part you have.

Topology within the domain is not uniform, and the shape changes what a collective should do. A direct mesh gives a pair one link's worth of bandwidth and its aggregate only when every GPU is participating; a switched fabric lets a pair use a GPU's whole link budget. This is why the same collective on the same rank count can behave differently on the two vendors, and why D03 §3.6's topology detection exists. Lab 1 makes your own node's shape visible.

3.3 The scale-out fabrics, and what is actually public about them

Four families are worth knowing by mechanism. Where this curriculum has an anchored source, it is cited; where it does not, the text says so instead of asserting.

InfiniBand. The traditional HPC choice, and the reference implementation of the ideas the others borrow. Three properties define it:

  • Verbs as the programming interface. Applications post work requests to queues rather than calling send(). Section 3.4 covers the mechanics; the important point here is that the interface is asynchronous and descriptor-based by design, not as an optimization.
  • A lossless link layer via credit-based flow control. A sender may only transmit when it holds credits proving the receiver has buffer space. Packets are therefore not dropped for congestion at all, which is what lets the transport layer be simple and the latency low. This is a genuinely different design point from Ethernet, which historically drops and retransmits.
  • Reliable Connection and Unreliable Datagram transports. RC gives a reliable, ordered, connection-oriented channel that supports one-sided RDMA READ and WRITE — and requires per-peer connection state. UD is connectionless, carries no RDMA operations, and needs far less state. The scaling consequence is important and often missed: a job where every rank keeps an RC queue pair to every other rank holds O(N^2) connections in aggregate, and the per-rank state grows with N. This is one of the real reasons very large jobs prefer hierarchical communication patterns and transports designed to avoid per-peer state.

RoCEv2 — the same verbs over Ethernet. RoCEv2 encapsulates InfiniBand transport in UDP over IP, so the application-facing verbs are unchanged and the fabric is standard Ethernet switching. That is an enormous operational advantage and it comes with one large catch: the verbs assume a nearly lossless link layer, and Ethernet does not provide one by default. So RoCE deployments configure Priority Flow Control (PFC), which lets a congested port pause its upstream neighbour, plus ECN-based end-to-end congestion control so senders slow down before pausing becomes necessary.

The failure mode is worth understanding in detail, because it is the most common way an expensive network underperforms a cheap one:

Congestion spreading. PFC operates hop by hop. A hot receiver pauses the switch port feeding it; that switch's buffers fill; it pauses its upstream; and the pause propagates backwards through the fabric. The traffic that gets stalled includes flows that were never going anywhere near the congested destination — they are simply queued behind a paused flow on a shared port. That is head-of-line blocking, and its effect is that one badly-behaved destination degrades unrelated jobs. In the worst case a cyclic buffer dependency produces a PFC deadlock, where a region of the fabric stops entirely.

The tuning principle that follows is simple to state and hard to execute: ECN must fire before PFC does. ECN marking thresholds should be low enough that senders back off while buffers are still draining, leaving PFC as a last-resort safety net rather than the primary mechanism. Getting those thresholds right is fabric-specific, traffic-specific and genuinely difficult, which is why RoCE is described as fragile in section 6 despite being technically capable of matching InfiniBand.

AWS EFA with SRD. The cloud instance of the same problem, solved differently. The Elastic Fabric Adapter exposes an RDMA-style interface over AWS's network, and its Scalable Reliable Datagram transport is designed around spraying packets across many paths and providing reliability in the adapter, while explicitly not guaranteeing ordering. That trade is deliberate: multipath spraying avoids the hot spots that single-path routing creates, and dropping the ordering guarantee avoids both the head-of-line blocking of an ordered stream and the per-peer connection state of RC. The cost is that the layer above must tolerate reordering, which is why applications reach it through libfabric and a collectives plugin rather than raw verbs. This curriculum carries no anchored source for EFA or SRD, so treat this paragraph as orientation and verify against AWS's current documentation before designing against it.

HPE Slingshot. Ethernet-compatible at the edge, with a dragonfly topology, adaptive routing and fine-grained congestion control inside. It is the fabric under several of the largest public systems, and unusually for a production interconnect there is an independent measurement study: De Sensi et al. analyze it in depth including its congestion behaviour, which makes it the best available public worked example of "what does congestion control actually buy". Three design choices are worth carrying forward: Ethernet compatibility so standard NICs and storage can attach, adaptive routing so a packet can be steered away from a congested global channel rather than queueing behind it, and congestion control aware of individual flows rather than only of link occupancy. The topology itself is D05's subject; the reason it needs adaptive routing — a minimally-routed dragonfly packet crosses at most one global channel, so a hot global channel is unavoidable without non-minimal paths — is Kim et al.'s, and the alternative shape, the fat-tree, is what most AI clusters build instead.

Family Link layer Transport model Distinguishing mechanism Main operational risk
InfiniBand lossless, credit-based RC and UD verbs simple transport because the link does not drop per-peer RC state at very large N
RoCEv2 Ethernet, made near-lossless with PFC same verbs over UDP/IP reuses commodity Ethernet switching congestion spreading and PFC misconfiguration
EFA with SRD Ethernet-based, multipath reliable but unordered datagrams packet spraying, no ordering guarantee upper layer must handle reordering
Slingshot Ethernet-compatible Ethernet plus fabric-internal control adaptive routing and flow-aware congestion control dragonfly needs its routing to work correctly

3.4 RDMA mechanics: queues, registrations, and what zero-copy means

RDMA's data path has four objects and one habit of mind. The habit of mind is that nothing is a function call that returns when the work is done; everything is a descriptor you post and a completion you later observe.

%%{init: {'theme': 'base', 'themeVariables': {'primaryColor': '#F8FAFC', 'primaryBorderColor': '#DB2777', 'lineColor': '#64748B', 'fontFamily': 'Inter, sans-serif'}}}%%
flowchart LR
  subgraph SETUP["Once, at startup - expensive"]
    direction TB
    REG["Register memory region:<br/>pin pages, program the adapter,<br/>get local and remote keys"]
    QP["Create queue pair (send + receive queue)<br/>and a completion queue"]
    EX["Exchange keys and addresses<br/>out of band"]
    REG --> QP --> EX
  end

  subgraph STEADY["Per transfer - cheap, kernel not involved"]
    direction TB
    POST["Post a work request:<br/>opcode, local buffer, remote address, rkey"]
    DOOR["Ring the doorbell<br/>(a write to a mapped register)"]
    DMA["Adapter DMAs the payload<br/>straight out of the registered buffer"]
    COMP["Completion appears on the<br/>completion queue; poll or wait"]
    POST --> DOOR --> DMA --> COMP
  end

  EX --> POST

  classDef trackD fill:#DB2777,stroke:#0F172A,color:#fff
  classDef neutral fill:#F8FAFC,stroke:#DB2777,color:#0F172A
  class REG,DMA trackD
  class QP,EX,POST,DOOR,COMP neutral

Queue pairs. A QP is a send queue plus a receive queue, and it is the RDMA analogue of a socket. On a reliable connected transport it is bound to exactly one remote QP, which is where the per-peer state cost in section 3.3 comes from.

Work requests and completion queues. You post a work request describing an operation — an opcode, a scatter-gather list of local buffers, and for one-sided operations a remote address and key. The adapter executes it asynchronously and posts a completion to a completion queue. Your code either polls that queue (lowest latency, burns a core) or waits on an event (higher latency, frees the core). This split is not an implementation detail; it is the latency-versus-efficiency knob that every RDMA-based library exposes in some form.

Memory registration, and why it is expensive. Before the adapter can touch a buffer it must be registered: the pages are pinned so the kernel cannot move or swap them, the physical translations are programmed into the adapter, and a pair of keys is produced — a local key for your own operations and a remote key that you hand to a peer to authorize its access. Registration is a kernel operation that walks and pins pages, so its cost scales with the size of the region and it is orders of magnitude more expensive than the transfer it enables. Three consequences follow, and all three show up in real systems:

  • Registration is cached, not repeated. Every serious RDMA-based library keeps a registration cache keyed by address range, so a hot buffer is registered once and reused for the life of the job. This is why the first collective in a run is dramatically slower than the steady state, and why warm-up iterations must sit outside a timed window — the point D03 §4 makes about its sweep.
  • Pinned memory is a global resource. Pinned pages cannot be reclaimed under pressure, so a process that registers aggressively reduces what the kernel can do for everybody else on the node. Registration caches must therefore have eviction policies, and those policies have to interact correctly with an allocator that may hand the same virtual address to a different buffer later.
  • Buffer churn is the anti-pattern. Allocating a fresh communication buffer per iteration converts a cached registration into a fresh one every time. The fix is a persistent buffer pool, and it is one of the highest-yield changes available in a hand-written RDMA application.

One-sided versus two-sided. A two-sided operation (SEND matched by a pre-posted RECV) requires the receiver to participate: it must have posted a receive buffer, and it learns about the arrival through its own completion queue. A one-sided operation (RDMA WRITE, RDMA READ) names the remote address directly and completes without the remote CPU doing anything at all — the remote side is not notified unless you arrange notification separately, for instance with a write to a flag after the payload, or a WRITE_WITH_IMM. One-sided operations are what make RDMA qualitatively different from fast messaging, and they are also where the hard bugs live, because you have taken responsibility for ordering and for telling the peer that its memory changed.

Kernel bypass. After setup, the data path does not enter the kernel. The doorbell is a write to a memory-mapped adapter register, and completions are read from a buffer the adapter writes. This is what removes tens of microseconds of system-call and protocol-stack cost from every message, and it is the other half of why RDMA latency is measured in single-digit microseconds.

So what does "zero-copy" actually mean? Precisely this: no CPU-executed copy between the application's buffer and the wire. The adapter's DMA engine reads the bytes from the buffer your application already had, and on the far side writes them into the buffer the peer already had. It does not mean no data movement — the bytes still cross PCIe and the wire, and those traversals are the irreducible cost. It also does not mean free: registration was the price, paid earlier. A useful way to say it in review is that zero-copy removes the copies that carry no information, and leaves exactly the ones that do.

3.5 GPUDirect RDMA and peer-to-peer DMA: taking the host off the path

Everything in 3.4 describes an adapter reading host memory. The extension that matters for GPUs is an adapter reading and writing device memory directly.

The mechanism is peer-to-peer DMA over PCIe. The GPU exposes a region of its device memory through a PCIe base address register (BAR), which makes that memory addressable to other PCIe devices. The network adapter, which is also a PCIe device, can then DMA to and from those addresses. Combined with registration of the device buffer, the result is a path from one GPU's HBM to a remote GPU's HBM with no host buffer anywhere in it. NVIDIA documents this as GPUDirect RDMA; ROCm exposes an equivalent peer-to-peer path, and because the supported combinations of kernel, driver and adapter change between releases, the authoritative statement of what works on your stack is the ROCm documentation portal for the version you have installed rather than any summary here.

Two practical facts do the most damage when they are not known.

The fast path has a topology requirement. Peer-to-peer DMA between an adapter and a GPU works best — and on some platforms only works at all — when the two devices sit under the same PCIe switch or at least the same root complex. A transfer that has to traverse the inter-socket link between two root complexes, or be routed by the host bridge, is a different and slower path. This is why cluster node designs pair each adapter with specific GPUs on a shared switch, and why AMD's cluster design reference is a document about topology as much as about bandwidth.

A mismatch usually degrades silently. This is the part worth internalizing. If the fast path is unavailable, the software stack will very often fall back to staging through host memory and still work correctly. There is no error, no warning in the common case, and no incorrect result — only a number that is two to five times worse than you expected, on a system you have already paid for. The same is true one level up: a peer-to-peer GPU-to-GPU copy on a pair with no direct link falls back to a host-staged copy and returns success. Silent correctness with quiet degradation is the defining hazard of this layer, and it is the reason section 4 spends its first lab on making the topology visible and its second on measuring a pair rather than assuming it.

%%{init: {'theme': 'base', 'themeVariables': {'primaryColor': '#F8FAFC', 'primaryBorderColor': '#DB2777', 'lineColor': '#64748B', 'fontFamily': 'Inter, sans-serif'}}}%%
flowchart TD
  SYM["Inter-node bandwidth is a<br/>fraction of the adapter rate"] --> Q1{"Is the GPU-to-GPU path<br/>inside the node direct?"}
  Q1 -->|"No - host hop in the matrix"| FIXTOPO["Rank placement or peer access.<br/>Lab 1 shows it; fix placement<br/>before touching the network"]
  Q1 -->|"Yes"| Q2{"Are the adapter and the GPU<br/>under the same PCIe switch<br/>or root complex?"}
  Q2 -->|"No"| FIXAFF["Cross-socket or host-bridge path.<br/>Bind ranks to the adapter that<br/>matches their GPU"]
  Q2 -->|"Yes"| Q3{"Is the direct device-memory<br/>path actually in use?"}
  Q3 -->|"No or unknown"| FIXGDR["Silent fallback to host staging.<br/>Check driver, adapter support and<br/>host CPU use during transfers"]
  Q3 -->|"Yes"| Q4{"Does per-node bandwidth rise<br/>when you add adapters?"}
  Q4 -->|"Yes"| FIXINJ["Injection-bound: adapters per node<br/>is the ceiling, not the wire.<br/>Section 3.6"]
  Q4 -->|"No"| FIXFAB["Fabric side: congestion, routing,<br/>oversubscription, or a degraded link.<br/>Sections 3.3 and 6"]

  classDef trackD fill:#DB2777,stroke:#0F172A,color:#fff
  classDef neutral fill:#F8FAFC,stroke:#DB2777,color:#0F172A
  class SYM trackD
  class Q1,Q2,Q3,Q4,FIXTOPO,FIXAFF,FIXGDR,FIXINJ,FIXFAB neutral

3.6 Injection bandwidth: why one adapter for eight GPUs is a ceiling

D01 §3.2 introduced LogP's gap parameter g — the minimum interval between consecutive message injections, whose reciprocal is the injection rate. The parameter looks abstract in the model and is completely concrete in a node: injection rate is a property of the node's network adapters, not of its GPUs.

Write it out. With n_nic adapters each sustaining B_nic bytes per second, and n_gpu GPUs sharing them:

node injection bandwidth   = n_nic * B_nic
per-GPU share              = n_nic * B_nic / n_gpu

Now compare that per-GPU share against the scale-up link bandwidth from the ladder in section 2.1. A node with eight GPUs and one adapter gives each GPU one eighth of one adapter — roughly two orders of magnitude below what the same GPU sees to its in-node neighbours. That is the cliff, and it is why:

  • Adding GPUs to a node does not add network bandwidth. Demand scales with GPU count; supply does not. Efficiency per GPU falls with every GPU you add, which is the opposite of the intuition that denser nodes are better.
  • busbw measured within a node tells you nothing about multi-node busbw. The intra-node number is bounded by scale-up links; the multi-node number is bounded by injection. A healthy single-node sweep followed by disappointing multi-node numbers is not a mystery, it is arithmetic — the case D03 §6.4 hands to this module.
  • One adapter per GPU is the design that makes injection scale, and wiring the n-th GPU of every node onto the same switch makes a collective step stay within one rail instead of contending for a shared uplink. That is the rail-optimized design, and D05 derives it properly.

tools/injection_model.py computes the ceiling and the per-GPU share for a configuration you describe, and prints the ratio against a scale-up bandwidth you supply, so you can see the cliff for the node you are actually considering. It is a model and says so.

The reason this deserves its own section rather than a footnote is that injection is the most common place where a purchasing decision and a performance decision collide. Adapters cost money and switch ports; the temptation to fit fewer is real; and the resulting ceiling is invisible in every single-node benchmark anyone will run during evaluation.

3.7 PCIe: the hidden bottleneck in the middle

Both fast tiers in this module talk to each other through PCIe, and PCIe is where the surprises are. The GPU-to-adapter hop is PCIe. The GPU-to-host hop is PCIe. In the staged path from section 2.3, PCIe is traversed twice per side. So even a design with a superb scale-up fabric and a superb network can be limited by the link in between, and that link is the one nobody puts on a slide.

Five specific things go wrong, all of them checkable in minutes:

  • Fewer lanes than expected. A device in a physically-x16 slot may be electrically narrower, or the platform may have bifurcated the lanes. Half the lanes is half the bandwidth.
  • A link trained to a lower generation. Signal integrity problems, a riser, or a cable can cause a link to negotiate a slower rate than both ends support. It works perfectly and it is slow.
  • A shared switch uplink. Several GPUs and an adapter under one switch may share an uplink whose bandwidth is less than the sum of theirs. Contention then depends on which devices are busy simultaneously — so the same code is fast alone and slow under load.
  • The wrong root complex. An adapter attached to socket 0 serving a GPU attached to socket 1 sends every byte across the inter-socket link, and pays for a host-bridge or cross-socket traversal that the topology matrix will show you if you look.
  • NUMA affinity ignored. Host staging buffers allocated on the far NUMA node add a cross-socket memory traversal to every transfer, and the process's CPU threads may be scheduled on the wrong socket entirely. This one is free to fix and routinely left broken.

The practical instruction is to treat PCIe as a first-class part of the fabric rather than as plumbing. Read the topology matrix (Lab 1), confirm negotiated link width and speed, and place ranks and buffers with the topology in mind. Every item on that list is a configuration change, not a purchase, which makes this the highest return-per-hour section of the module.


4. Hands-On Labs

Labs 1 and 2 run on any node with at least two GPUs and produce real, reproducible output. Lab 3 needs an RDMA-capable fabric with the userspace verbs tools installed, and will simply not exist on a laptop or on most cloud instances — that is expected, and the lab says what to do instead. Lab 4 is analytic and runs anywhere with the Python standard library.

cd tracks/D-distributed-computing/D04.interconnects-and-rdma
make            # builds hip/peer_copy_bw.cpp with hipcc
make cuda       # builds cuda/peer_copy_bw.cu with nvcc
make report     # lab 1's topology capture plus the lab 4 models

Vendor command-line tools change flags between releases. Every invocation below is written for the current tools at the time of writing; if one is rejected, check --help rather than assuming the lab is wrong.

Lab 1 — Read your node's topology matrix

Goal: for every pair of GPUs in your node, be able to say whether they have a direct link or a host hop — and to say the same for each GPU-to-adapter pair. This is the single most useful skill in the module, and it takes ten minutes.

# AMD / ROCm
rocm-smi --showtopo                 # link type, hop count, and NUMA node per pair
rocm-smi --showtopo | tee topo.txt
amd-smi topology                    # newer ROCm; same information, different layout

# NVIDIA / CUDA
nvidia-smi topo -m                  # the pair matrix, including NIC rows and NUMA affinity
nvidia-smi topo -m | tee topo.txt
nvidia-smi topo -p2p r              # peer-to-peer read capability, pair by pair

# normalize either vendor's output into one comparable table
python3 tools/topology_report.py --input topo.txt --vendor auto

What to observe, in this order:

  1. The legend, before the matrix. NVIDIA's classes run from X (self) and NV# (a direct scale-up link, with the number of links) down through PIX, PXB, PHB, NODE and SYS — a ladder of increasingly distant PCIe paths, ending with a traversal between sockets. ROCm reports link type, hop count and a NUMA distance per pair. The class, not the number of hops, is what tells you which tier of section 2.1 a pair is in.
  2. Find the pairs with no direct link. In a full-mesh or fully-switched node there are none. In many real machines there are some, and if your tensor-parallel group happens to span such a pair, that group's collective runs one tier down for no reason. This is a placement bug and it is free to fix.
  3. Read the adapter rows. For each network adapter, note which GPUs share its PCIe switch. Those are the GPUs with a fast path to it; the others do not have one. Compare against which GPU your rank actually uses, and against the NUMA column.
  4. Note the NUMA affinity column and believe it. If your process is pinned to the wrong socket for its GPU, every host-staged transfer pays a cross-socket traversal, and section 3.7's list tells you what that costs.

Save the output. It is the input to Lab 2's interpretation and to the exercises, and a captured topology matrix is the single most useful artifact to attach to a performance bug report.

Lab 2 — Measure a GPU pair, do not assume it

Goal: get real bandwidth for one GPU pair, and see for yourself what happens on a pair with no direct link.

The vendor tools first, because they are the fastest route to a number:

# AMD: unidirectional and bidirectional copy bandwidth for every device pair
rocm-bandwidth-test

# NVIDIA: from the CUDA samples, builds standalone
./p2pBandwidthLatencyTest

Then the minimal program, so that nothing is hidden. Every runtime call is checked, the result is verified byte for byte, and warm-up sits outside the timed region because the first copy pays path setup. hip/peer_copy_bw.cpp:

// Unidirectional peer-to-peer copy bandwidth between two GPUs, verified.
// Build: hipcc -O2 hip/peer_copy_bw.cpp -o peer_copy_bw
// Run:   ./peer_copy_bw [src_dev] [dst_dev] [bytes]
#include <hip/hip_runtime.h>

#include <cstdio>
#include <cstdlib>
#include <vector>

#define HIP_CHECK(cmd)                                                       \
  do {                                                                       \
    hipError_t e_ = (cmd);                                                   \
    if (e_ != hipSuccess) {                                                  \
      std::fprintf(stderr, "HIP %s:%d '%s': %s\n", __FILE__, __LINE__, #cmd, \
                   hipGetErrorString(e_));                                   \
      std::exit(EXIT_FAILURE);                                               \
    }                                                                        \
  } while (0)

int main(int argc, char** argv) {
  const int src_dev = (argc > 1) ? std::atoi(argv[1]) : 1;
  const int dst_dev = (argc > 2) ? std::atoi(argv[2]) : 0;
  const size_t bytes =
      (argc > 3) ? (size_t)std::strtoull(argv[3], nullptr, 10)
                 : ((size_t)256 << 20);
  const int iters = 20;

  int ndev = 0;
  HIP_CHECK(hipGetDeviceCount(&ndev));
  if (ndev < 2 || src_dev < 0 || dst_dev < 0 || src_dev >= ndev ||
      dst_dev >= ndev || src_dev == dst_dev) {
    std::fprintf(stderr, "need two distinct valid device ids; found %d\n", ndev);
    return EXIT_FAILURE;
  }
  if (bytes == 0) {
    std::fprintf(stderr, "byte count must be positive\n");
    return EXIT_FAILURE;
  }

  // The teaching point of this lab: when this is 0, the copy below still
  // succeeds -- it silently stages through host memory (section 3.5).
  int can_access = 0;
  HIP_CHECK(hipDeviceCanAccessPeer(&can_access, dst_dev, src_dev));
  std::printf("device %d reading device %d: %s\n", dst_dev, src_dev,
              can_access ? "direct peer path" : "NO direct path, will stage");

  HIP_CHECK(hipSetDevice(dst_dev));
  if (can_access) {
    hipError_t e = hipDeviceEnablePeerAccess(src_dev, 0);
    if (e != hipSuccess && e != hipErrorPeerAccessAlreadyEnabled) {
      std::fprintf(stderr, "hipDeviceEnablePeerAccess: %s\n",
                   hipGetErrorString(e));
      return EXIT_FAILURE;
    }
    (void)hipGetLastError();  // clear the recorded already-enabled error
  }

  unsigned char* src = nullptr;
  unsigned char* dst = nullptr;
  HIP_CHECK(hipSetDevice(src_dev));
  HIP_CHECK(hipMalloc(&src, bytes));
  HIP_CHECK(hipMemset(src, 0xAB, bytes));
  HIP_CHECK(hipDeviceSynchronize());

  HIP_CHECK(hipSetDevice(dst_dev));
  HIP_CHECK(hipMalloc(&dst, bytes));
  HIP_CHECK(hipMemset(dst, 0x00, bytes));

  hipStream_t stream;
  hipEvent_t t0, t1;
  HIP_CHECK(hipStreamCreate(&stream));
  HIP_CHECK(hipEventCreate(&t0));
  HIP_CHECK(hipEventCreate(&t1));

  for (int i = 0; i < 3; ++i) {  // warm-up: first copy pays path setup
    HIP_CHECK(hipMemcpyPeerAsync(dst, dst_dev, src, src_dev, bytes, stream));
  }
  HIP_CHECK(hipStreamSynchronize(stream));

  HIP_CHECK(hipEventRecord(t0, stream));
  for (int i = 0; i < iters; ++i) {
    HIP_CHECK(hipMemcpyPeerAsync(dst, dst_dev, src, src_dev, bytes, stream));
  }
  HIP_CHECK(hipEventRecord(t1, stream));
  HIP_CHECK(hipStreamSynchronize(stream));

  float ms = 0.0f;
  HIP_CHECK(hipEventElapsedTime(&ms, t0, t1));
  const double secs = (double)ms / 1000.0;
  const double gbs = (double)bytes * (double)iters / secs / 1e9;

  // A fast wrong answer is the worst outcome, so check every byte.
  std::vector<unsigned char> host(bytes);
  HIP_CHECK(hipMemcpy(host.data(), dst, bytes, hipMemcpyDeviceToHost));
  size_t wrong = 0;
  for (size_t i = 0; i < bytes; ++i) {
    if (host[i] != 0xAB) {
      ++wrong;
    }
  }

  std::printf("%zu MiB x %d iters: %.1f GB/s unidirectional, %zu wrong bytes\n",
              (size_t)(bytes >> 20), iters, gbs, wrong);

  HIP_CHECK(hipEventDestroy(t0));
  HIP_CHECK(hipEventDestroy(t1));
  HIP_CHECK(hipStreamDestroy(stream));
  HIP_CHECK(hipFree(dst));
  if (can_access) {
    HIP_CHECK(hipDeviceDisablePeerAccess(src_dev));
  }
  HIP_CHECK(hipSetDevice(src_dev));
  HIP_CHECK(hipFree(src));

  return wrong == 0 ? EXIT_SUCCESS : EXIT_FAILURE;
}

The NVIDIA version, cuda/peer_copy_bw.cu, is the same file with the mechanical substitution D03 §4 tabulates: hip becomes cuda throughout, hipErrorPeerAccessAlreadyEnabled becomes cudaErrorPeerAccessAlreadyEnabled, and hipcc becomes nvcc. Nothing about the logic changes.

What to observe. Four things:

  1. 0 wrong bytes, always. If the verification fails, stop and fix that before looking at a bandwidth number.
  2. The reported bandwidth for a pair that Lab 1 said has a direct link, compared against the link rate for your hardware from B01 §3.5. Expect a fraction of the specified figure, and expect roughly half if you compare a unidirectional copy against a bidirectional specification — the factor-of-two trap B01 warns about.
  3. The same measurement on a pair Lab 1 said has no direct link. It still prints a number, and the number is much lower. That is the silent fallback of section 3.5, reproduced in one command, and it is the shape of the bug you will meet in production.
  4. Host CPU utilization during the run, in another terminal. The direct path barely touches it; a staged path does not.

Lab 3 — RDMA device discovery and a two-node bandwidth test

Goal: see the verbs layer as a real thing with real properties, and get one honest inter-node number.

[!NOTE] This lab requires an RDMA-capable adapter, its kernel modules loaded, and the userspace tools (rdma-core and perftest, packaged under various names). On a machine without RDMA these commands do not exist or report no devices. That is a correct result, not a failed lab. If it is your situation, read the cached transcripts under outputs/, then go to Lab 4 which models what you cannot measure.

# What adapters exist, and what do they claim?
ibv_devices                      # list device names
ibv_devinfo -v                   # per-device: ports, state, MTU, rates, capabilities
ibstat                           # link state and physical state per port

# Bandwidth between two hosts. Run the server on one, the client on the other.
# host A:
ib_write_bw -d mlx5_0 --report_gbits
# host B:
ib_write_bw -d mlx5_0 --report_gbits <hostA>

# Latency, which is a different question and a different tool:
ib_write_lat -d mlx5_0 <hostA>

# Error counters -- read these before and after, not only after:
cat /sys/class/infiniband/mlx5_0/ports/1/counters/*

If your perftest build supports GPU buffers, the same tool can drive the device-memory path directly (--use_rocm=<device> on ROCm builds, --use_cuda=<device> on CUDA builds). When it does, run it both ways: the difference between a host-buffer and a device-buffer transfer on the same pair of hosts is the most direct measurement of section 3.5 available to you. Check ib_write_bw --help first, because these flags depend on how the package was compiled.

python3 tools/parse_ib_bw.py --input ib_write_bw.log --report gbits

What to observe:

  1. Port state must be Active and physical state LinkUp before any number means anything. A port in Init or Down is a cabling or subnet-manager problem, not a performance problem.
  2. The negotiated rate and MTU from ibv_devinfo, and whether they are what you were sold. A port running below its capable rate is the fabric equivalent of section 3.7's trained-down PCIe link.
  3. The units. --report_gbits reports gigabits per second; the rest of this curriculum works in gigabytes per second. The factor is eight, and mixing the two is the most common arithmetic error in fabric discussions. tools/parse_ib_bw.py prints both and labels them.
  4. The small-message rows versus the large-message rows. The small end is your alpha, the large end is your beta, and the crossover between them is D01 §3.1's m* measured on your own fabric rather than assumed.
  5. The error counters, as a delta. Counters are cumulative since boot, so an absolute value tells you almost nothing. A counter that increments during your run is a degraded link, and section 6 explains why that is worse than a link that fails outright.

Lab 4 — Model what you cannot measure

Goal: put numbers on the staged-versus-direct comparison and on the injection ceiling for a node you are considering, before anybody buys it.

python3 tools/staging_cost.py --bytes 1073741824 --pcie-gbs 20 --net-gbs 10
python3 tools/injection_model.py --gpus-per-node 8 --nics-per-node 1 \
        --nic-gbs 25 --scaleup-gbs 400
python3 tools/injection_model.py --gpus-per-node 8 --nics-per-node 8 \
        --nic-gbs 25 --scaleup-gbs 400

Both tools print a banner marking their output as a model, not a measurement, exactly as the rest of Track D does.

What to observe. In staging_cost.py, the gap between the serial bound and the pipelined bound — and that the pipelined bound becomes indistinguishable from the direct path once PCIe is comfortably wider than the wire. That is section 2.3's honest conclusion, and it should make you suspicious of any blanket claim that the direct path is k times faster. In injection_model.py, run the two invocations back to back and read the per-GPU share and the ratio against the scale-up tier. One adapter for eight GPUs puts each GPU roughly two orders of magnitude below its in-node bandwidth; eight adapters restore the ratio to roughly one. Then sweep --nics-per-node and note that the curve is linear with no diminishing returns until it hits --nic-gbs times the count, which is precisely why the rail-optimized design in D05 exists.


5. Performance Analysis

[!NOTE] Single-node topology output and single-node pair bandwidth are real and reproducible — Labs 1 and 2 measure them on whatever hardware you have, and sanitized reference transcripts live under outputs/, labelled with the hardware they came from. Everything in this module about multi-node behaviour is either a cited public figure or an analytic model that announces itself as one. No number here is published that this repository cannot reproduce or attribute.

5.1 How to read a topology matrix

A topology matrix looks like a table of codes and is actually a map of section 2.1's ladder. Read it in four passes, in this order, because each pass can make the next unnecessary:

Pass What you are looking for What a bad answer means
1. Legend Which codes mean a direct scale-up link, and which mean a PCIe or host path You cannot interpret anything until you have this; the codes differ by vendor and by tool version
2. GPU-to-GPU pairs Whether every pair in each parallelism group has a direct link A group spanning a host hop runs its collective one tier down. Fix by placement, not by tuning
3. GPU-to-adapter rows Which GPUs share a PCIe switch with each adapter A rank using an adapter on a different switch or socket has no fast device-memory path
4. NUMA column Whether the process's CPU and memory affinity match its GPU Every host-staged byte pays a cross-socket traversal, and the fix is free

The habit to build is to capture this matrix as part of every performance investigation, alongside the software versions. Roughly, a distributed performance problem is either a placement problem, an injection problem or a fabric problem, and pass 2 and pass 3 rule out the first one in under a minute.

5.2 How to read a bandwidth-test result

Whether the number came from a peer-copy test, rocm-bandwidth-test, p2pBandwidthLatencyTest, ib_write_bw, the OSU micro-benchmarks or nccl-tests / rccl-tests, the same seven questions decide whether it means anything:

  1. Bytes or bits? Gigabits per second is eight times gigabytes per second. Convert once, at the start, and label the unit everywhere.
  2. Unidirectional or bidirectional? A bidirectional specification compared against a unidirectional measurement produces an apparent 50% efficiency that is entirely an accounting error. B01 §3.5 flags this as a factor-of-two trap for exactly this reason.
  3. What message size? A single bandwidth number without its message size is uninterpretable. The small end measures alpha, the large end measures beta, and quoting only one of them hides half the fabric's behaviour.
  4. Was it warmed up? The first transfer pays connection setup and memory registration (section 3.4). Including it in an average understates steady-state bandwidth; reporting it separately is a legitimate and useful measurement of setup cost.
  5. How many outstanding operations? A single in-flight transfer measures the latency-bandwidth product, not the link. Depth is a parameter of the measurement, and a low number at depth one is not a broken link.
  6. Which path did it actually take? This is the question section 3.5 exists for. A number produced by a silent host-staged fallback is a correct measurement of the wrong thing.
  7. Was anything else running? Shared PCIe switches, shared uplinks and other tenants all make bandwidth a function of the neighbourhood. A number without its context is not reproducible.

5.3 What is measurable here and what is modelled

The boundary is worth restating plainly, because it is the difference between this module and a vendor deck. You can measure: your topology matrix, negotiated PCIe and port rates, peer-to-peer bandwidth and latency for every GPU pair in your node, the staged-versus-direct difference on your own machine if your perftest build supports device buffers, and error-counter deltas. You cannot measure here, and this module therefore models or cites: anything about a multi-node fabric at scale, congestion behaviour under load from other tenants, and the effect of topology — for which the honest sources are the cited studies and the specifications, not an extrapolation. Per-part scale-up figures with retrieval dates are in B01 §3.5; the fabric specifications belong to their vendors and should be quoted with the date you retrieved them, because they are revised.

5.4 Tying it to the roofline

B02 classifies a kernel by arithmetic intensity: FLOPs per byte moved from HBM. This module is the same framework with the denominator replaced, one tier at a time. A flow's intensity is FLOPs per byte moved in the tier it was placed in, so moving a flow one tier down the ladder divides its effective intensity by roughly ten without changing a line of code. Two consequences follow directly:

  • A workload that is comfortably compute-bound within a node can be firmly bandwidth-bound the moment the same traffic crosses to the network tier. The roofline did not change; the flow moved to a different roofline.
  • The three levers the roofline names for a bandwidth-bound kernel are the only three available here too: move fewer bytes, move them in a faster tier, or move them at the same time as something else. "Buy a faster fabric" is only the second of those, and it is usually the most expensive one.

That is why section 2.2's rule is stated in terms of tier placement rather than in terms of bandwidth procurement. Placement is the lever with the best ratio of leverage to cost, and it is available today on hardware you already own.


6. Challenges, Drawbacks & Tradeoffs

6.1 Lossless Ethernet, and the congestion that spreads

RoCEv2's appeal is that it delivers RDMA semantics on commodity Ethernet. Its risk is that those semantics assume a link layer that does not drop, and making Ethernet behave that way requires configuring PFC and ECN correctly across every switch in the path. When that configuration is wrong, the result is not "slightly worse than InfiniBand" — it is a network that is worse than the lossy Ethernet it replaced, for the reason in section 3.3: PFC pauses propagate backwards hop by hop, so congestion at one destination stalls flows that never touched it, and head-of-line blocking spreads the damage to unrelated jobs. In the pathological case a cyclic buffer dependency produces a PFC deadlock and a region of the fabric stops.

Three review questions catch most of it. Does ECN fire before PFC? If PFC is doing the primary work, the design is inverted. Is the configuration consistent on every hop? A single switch with different thresholds is enough to create a hot spot that appears intermittently. Is anyone watching pause frames? Pause counters are the leading indicator of this entire failure class, and they are usually unmonitored until an incident.

The honest tradeoff is organizational as much as technical: InfiniBand moves this complexity into a purpose-built fabric with a subnet manager and a smaller configuration surface, at the price of a separate network to operate and a narrower supplier base. RoCE keeps one network and one operational model, and asks your network team for tuning that is genuinely difficult. Either can be right; what is never right is choosing RoCE for its simplicity and then not doing the tuning.

6.2 The costs that a bandwidth number does not show

Concern Why it bites What to do about it
Memory registration cost Registration pins pages and programs the adapter; it is orders of magnitude more expensive than the transfer it enables, so per-iteration buffers turn a cached registration into a fresh one every step Persistent buffer pools; register hot buffers once; keep warm-up outside timed regions
Pinning pressure Pinned pages cannot be reclaimed, so aggressive registration takes memory away from everything else on the node, including other ranks Bound the registration cache; monitor pinned totals; treat it as a shared resource
Silent GPUDirect fallback The staged path is correct, so a missing fast path produces no error and no wrong answer — just a number two to five times worse Verify the path explicitly (Lab 2 and Lab 3); watch host CPU use during transfers; assert the expected bandwidth in a startup check
PCIe topology mistakes Lane count, negotiated generation, a shared switch uplink, or an adapter on the wrong root complex each silently divide your bandwidth Read the topology matrix at deployment; confirm negotiated width and speed; pair adapters with the GPUs on their switch
NUMA affinity A process pinned to the far socket adds a cross-socket traversal to every staged byte and to every host buffer Bind ranks to the NUMA node of their GPU and their adapter; it is a configuration change with no downside
Cable and link flap A degraded link that retrains or corrects errors is worse than a dead one: the job keeps running and one rank paces everybody, since a collective is a barrier Monitor error-counter deltas, not absolutes; health-gate before scheduling; drain suspicious links
One-sided operation hazards RDMA WRITE completes without notifying the peer, so ordering and notification are now your responsibility Use an explicit flag or an immediate-data variant; never infer arrival from a local completion
Vendor lock-in Scale-up fabrics are vendor-specific by construction, and tuning, plugins and operational knowledge do not transfer Keep the portable layer portable: program collectives through the library API, not the fabric; keep fabric-specific settings in configuration with dates and rationale
Cost Adapters, cables, optics and switch ports are a large fraction of cluster capital cost, and one adapter per GPU multiplies all four Size injection against the actual traffic pattern (section 3.6), and decide it explicitly rather than by default

6.3 When not to reach for the fast path

  • When the traffic is small and rare. Registration, pinning and topology work have a fixed engineering cost. A flow that moves a few megabytes at startup does not justify any of it.
  • When you have not confirmed which tier the traffic is in. Optimizing a transfer that is already in the scale-up domain by making it RDMA-aware is effort spent in the wrong tier.
  • When correctness is not yet established. One-sided RDMA moves ordering and notification into your code. Do not take that on until a working two-sided or library-mediated version exists to compare against.
  • When a library already does it. A collectives library, an MPI implementation or a storage client already implements registration caching, path selection and completion handling, and has been debugged at scale. Hand-written verbs code is justified by a measured gap, not by principle.

6.4 The scale-boundary table for the fabric

The same shape as D01 §6.4, specialized to the wire:

Regime Binding constraint First symptom Mitigation Where it is covered
2-8 GPUs, one node Scale-up topology, and whether peer access is actually in use A pair in your parallelism group shows a host hop; measured pair bandwidth is a small fraction of the link rate Place ranks on directly-linked GPUs; verify peer access; keep tensor parallelism inside the domain This module, 3.2 and Labs 1-2
GPU to adapter, one node The PCIe path between GPU and adapter Inter-node bandwidth is a fraction of the adapter rate; host CPU is busy during collectives Fast device-memory path; adapter and GPU on the same switch; confirm negotiated width and speed This module, 3.5 and 3.7
8-64 ranks Injection: adapters per node, LogP's g Multi-node bandwidth scales with node count but not with GPU count One adapter per GPU; rail-aware placement; bucket and overlap This module, 3.6, then D05
64-1k ranks Fabric congestion control and oversubscription Run-to-run variance; your time depends on other tenants' traffic ECN before PFC; adaptive routing; rail-optimized design; audit oversubscription D05
1k-10k ranks Link errors and flaps across a large cable plant One degraded link paces an entire job, because a collective is a barrier Error-counter delta monitoring; health-gated scheduling; drain and replace D06
10k+ ranks Cost and blast radius of the fabric itself; bisection bandwidth The network dominates capital cost; a switch failure removes a whole slice; all-to-all patterns collapse Topology choice; sub-communicators; keep global collectives off the critical path D06

7. Real-World Use Cases

Tensor parallelism confined to the scale-up domain. This is the most consequential design rule that follows from the whole module, and it is entirely a fabric argument. Tensor parallelism issues a collective twice per transformer layer, the payload is one activation tensor rather than a whole model, and during decode every one of those collectives is on the critical path of every token. Small, frequent, latency-critical traffic is exactly what the scale-out tier is worst at — recall from section 2.1 that latency degrades by about four orders of magnitude across the ladder while bandwidth degrades by two. So tensor parallelism stays inside the scale-up domain, and the width of that domain becomes a hard limit on how far a single model instance can shard before another axis has to take over. When you see a serving stack default to tensor parallelism within a node and pipeline or replication across nodes, this is the reason.

Gradient all-reduce over the scale-out fabric. The mirror image, and the traffic the scale-out tier is genuinely good at. The all-reduce payload is the size of the model, it happens once per step, and it can be bucketed so that reduction of early layers overlaps the backward pass of later ones. Large, infrequent, overlappable traffic tolerates a tier with high latency and adequate bandwidth. The constraint that actually binds is the injection ceiling from section 3.6 rather than the wire: this is the specific case where a node with eight GPUs and one adapter shows healthy single-node numbers and disappointing multi-node ones, and where D03's busbw plateau turns out to be a property of the adapter count rather than of the collective.

Storage and checkpoint traffic competing with collective traffic. Easy to forget, because it lives in a different part of the org chart. A checkpoint write, a dataset read and a container image pull all traverse the same PCIe complex and often the same fabric as your collectives, and they are bursty. Writing a large checkpoint synchronously in the middle of a step therefore does not merely add its own time; it steals bandwidth from the collective on the critical path, and the visible symptom is a step that is intermittently slow with no change in the model code. The mitigations are all forms of section 2.2's rule: make checkpoints asynchronous, stage them to local storage first, keep storage traffic on a different rail or adapter where the topology allows, and schedule bulk transfers away from collective phases. The failure-driven reason large systems checkpoint asynchronously belongs to D06; the bandwidth-contention reason belongs here.

Disaggregated inference. A newer pattern that is fabric-limited by construction: run the prefill phase on one pool of GPUs and the decode phase on another, because the two have very different arithmetic intensity and very different latency requirements. That split only works if the KV cache produced by prefill can reach the decode workers fast enough not to erase the benefit, which makes the transfer a first-class design constraint rather than plumbing. It is the clearest current example of a system design whose viability is decided by which tier of section 2.1 a single data flow lands in, and of why zero-copy device-to-device paths are worth their operational cost.

Where to go next. D05 takes the adapters this module put in a node and asks how to wire thousands of them together: fat-tree against dragonfly against torus, bisection bandwidth, oversubscription, and the rail-optimized design that section 3.6's injection argument implies. Read it next if your multi-node numbers depend on placement — that is a topology symptom, not a wire symptom. D06 then consolidates every Track D scale-boundary table against systems that were actually built, including the fabrics named in section 3.3 and the failure behaviour that section 6.2's error counters are trying to catch; the system specifications themselves change with each TOP500 list edition, which is why that module cites the edition rather than a static number.


8. Cited References

Shared sources, linked by anchor from REFERENCES.md:

On numbers in this module. This module is about hardware figures, which makes citation discipline more important here than anywhere else in Track D, so the policy is explicit. The tier ladder in section 2.1 is illustrative orders of magnitude, chosen to make the ratios between tiers visible and consistent with D01 §3.1; no row is a specification for any product. The staged-versus-direct arithmetic in section 2.3 and the injection arithmetic in section 3.6 use round invented inputs, labelled as such, to demonstrate a calculation rather than to report a measurement, and the tools that automate them print a model banner. Per-part scale-up figures with sources and retrieval dates exist in the curriculum exactly once, in B01 §3.5, and are referenced rather than paraphrased. Scale-out fabric rates are vendor specifications that are revised over time: look them up in the vendor documentation for the part you have and record the retrieval date alongside, exactly as B01 does. The EFA and SRD description in section 3.3 carries no anchored source and says so in place.


9. Self-Assessment & Interview Drills

Conceptual

  1. A colleague proposes running an 8-way tensor-parallel model across two nodes with four GPUs each, because "the network is fast enough — it is only a few hundred megabytes per step". What is wrong with the reasoning, and which measurement settles it?
  2. Your inter-node all-reduce bandwidth is roughly a quarter of what the adapter specification suggests. Everything is configured, nothing errors, and results are correct. Give the three most likely causes and the single piece of evidence that distinguishes them.
  3. Explain what "zero-copy" removes and what it does not. Then explain why a team can enable GPUDirect RDMA and observe almost no bandwidth improvement without either measurement being wrong.
  4. Why is memory registration expensive, and why does that cost push RDMA-based libraries toward persistent buffers rather than toward faster registration?
  5. A network team replaces InfiniBand with RoCEv2 on the same switches your storage traffic uses, and collective performance becomes intermittently much worse — including for jobs on nodes that are not involved in the congested transfers. Name the mechanism and the configuration principle that addresses it.
  6. You are given two node designs at the same price: eight GPUs with one network adapter, or four GPUs with four adapters. For which workload is each the better choice, and what quantity do you compute to decide?
Answers
  1. The reasoning uses the bandwidth ratio and the binding constraint is latency and tier crossing. Tensor parallelism issues a collective twice per layer, and during decode those collectives sit on the critical path of every token, so the relevant quantity is not bytes per step but fixed cost per collective times collectives per token. Crossing from the scale-up tier to the scale-out tier raises latency by roughly two to three orders of magnitude (section 2.1) while the payload stays small, which is precisely the regime where a fabric upgrade buys nothing. It settles with a small-message latency measurement across both tiers — a near-zero-byte collective inside the node and the same one across nodes — multiplied by the collective count per token. Note also that the total network bytes per step is the wrong denominator anyway, because the traffic is serialized with compute rather than overlappable.

  2. Three causes, all consistent with correct results and no errors:

  3. Injection ceiling. The node has fewer adapters than GPUs, so per-GPU bandwidth is n_nic * B_nic / n_gpu (section 3.6), not B_nic. Distinguish by holding GPU count fixed and adding adapters, or by running with only one GPU per node active: if per-GPU bandwidth jumps, you were injection-bound.
  4. Silent host staging. The fast device-memory path is unavailable and the stack fell back (section 3.5). Distinguish by watching host CPU utilization and host memory bandwidth during transfers — the direct path barely touches either, and staging cannot avoid both.
  5. PCIe path. Lane count, a trained-down link, a shared switch uplink, or an adapter on a different root complex from the GPU (section 3.7). Distinguish from the topology matrix plus negotiated width and speed, which is a one-minute check and should therefore be done first.

The general lesson is that all three are invisible in a correctness test and all three are cheap to rule out, which is why Lab 1 comes before any tuning.

  1. Zero-copy removes CPU-executed copies between the application's buffer and the wire — the staging into a pinned bounce buffer, the host memory traffic that carries, and the CPU time and synchronization that go with it. It does not remove data movement: the bytes still cross PCIe and the wire, and it does not make the operation free, because registration paid the cost earlier. So a team can enable it and see little bandwidth change whenever PCIe was not the narrow link — if PCIe is comfortably wider than the wire, doubling PCIe demand does not move the bottleneck, and a well-pipelined staged transfer approaches the direct path's throughput (section 2.3). What they should see instead is lower fixed latency per transfer, lower host CPU and host memory consumption, and less interference with the data loader and with other ranks. Bandwidth is simply the wrong metric for what the change bought.

  2. Registration must pin the pages so the kernel cannot move or swap them and program the physical translations into the adapter, which is a kernel operation whose cost scales with region size — orders of magnitude more than the transfer it enables. It cannot be made cheap, because the expensive parts are the pinning and the translation programming, which are intrinsic to letting a device DMA safely into process memory. Therefore the only real optimization is amortization: register once and reuse, which is a persistent buffer pool plus a registration cache. This also explains two familiar behaviours — the first collective in a run is much slower than the steady state, and allocating a fresh communication buffer each iteration is a serious performance bug rather than a stylistic one.

  3. The mechanism is congestion spreading through PFC back-pressure. RoCEv2 needs a near-lossless link layer, so PFC lets a congested port pause its upstream neighbour; that neighbour's buffers fill and it pauses its upstream, and the pause propagates backwards through the fabric. Flows sharing any port along that path are stalled behind a paused flow even though their destination was never congested — head-of-line blocking — which is why uninvolved jobs degrade. The configuration principle is that ECN must fire before PFC: end-to-end congestion notification should slow senders while buffers are still draining, leaving PFC as a last-resort safety net rather than the primary control loop. Consistency across every hop matters as much as the thresholds themselves, and pause-frame counters are the leading indicator to monitor. The storage traffic sharing the fabric is an aggravating factor, not the cause: it makes the hot spots more frequent and burstier.

  4. Compute the per-GPU injection share, n_nic * B_nic / n_gpu, and compare it against the scale-up bandwidth available to the same GPU. Eight GPUs with one adapter gives each GPU one eighth of one adapter while giving it a full scale-up link to seven neighbours — an excellent design for work that keeps its traffic inside the node, such as a model that fits in one node's scale-up domain with tensor parallelism, or independent inference replicas. Four GPUs with four adapters gives each GPU a whole adapter, which is what network-heavy work needs: large-scale data-parallel training where the gradient all-reduce crosses nodes every step, or any job whose collectives are dominated by inter-node traffic. The deciding question is therefore not which node is faster but what fraction of your traffic crosses the node boundary — which is a property of your parallelism plan, and is exactly why the fabric decision cannot be made before the sharding decision.

Coding & Algorithms

  1. Topology classifier. Write a parser that reads a captured nvidia-smi topo -m or rocm-smi --showtopo output and emits, for every GPU pair, a normalized class from a small enumeration — self, direct-link, pcie-switch, pcie-host, cross-socket, unknown — plus the same for every GPU-to-adapter pair. Then add a worst_class_in_group(gpus) helper that returns the worst class within a proposed parallelism group, so a launcher can refuse a bad placement. Fail with a one-line message and a non-zero exit on unparseable input; never raise a traceback.

  2. Staged versus direct cost model. Implement staged_cost(m, pcie_bps, net_bps) and direct_cost(m, pcie_bps, net_bps) returning both the serial sum of segments and the pipelined bound (the busiest single resource, accounting for PCIe being traversed twice per side in the staged case). Then write crossover_pcie_bps(...) returning the PCIe bandwidth below which the staged path becomes bandwidth-limited rather than merely latency- and host-limited. Validate against section 2.3's round numbers, and reject non-positive bandwidths with ValueError.

  3. Injection ceiling. Implement per_gpu_injection(n_nic, nic_bps, n_gpu) and a function returning the ratio against a supplied scale-up bandwidth. Then, given a target ratio, return the minimum n_nic that achieves it. Verify that the function is linear in n_nic, that n_gpu growth degrades it proportionally, and that n_nic = n_gpu is the point where the ratio stops depending on GPU count. Handle zero adapters as a defined error, not a division by zero.

  4. Peer-copy bandwidth harness. Extend Lab 2's program into a sweep: for every ordered pair of devices, report unidirectional bandwidth at several message sizes, and report whether hipDeviceCanAccessPeer / cudaDeviceCanAccessPeer was true for that pair. Keep every return code checked and keep the byte-for-byte verification. Then cross-check the resulting matrix against Lab 1's topology classes and flag any pair whose measured bandwidth is inconsistent with its reported class — that flag is the automated form of section 3.5's silent-fallback detector.

Starter files with TODOs are in exercises/; worked solutions with commentary are in solutions/.